Today we got to dig into the UCSM interface some more. One thing we discussed pretty heavily is that
the Service Profile assignment is confusing when slot and server are used
interchangeably. Questions like “Do you
apply a Service Profile to a server or a slot” came up (answer: slot). But then, when stepping through the creation
process in UCSM, we came across this:
Figure 1: Associating a Service Profile
Note that your two options are to associate it to a slot or
a server. Confused? We were too.
The end result: you apply a service profile to a slot, not a
server. If a server is removed from one
slot and inserted into another slot, the profile does NOT move with it. Our advice to Cisco was to clean up the
interface by eliminating the use of the word “server” and ensure consistency
with the different parts of the interface.
Why eliminate the word “server?” Well, what is a server? That can be a very subjective term. In UCS terms, I view the server as the
convergence of the blade hardware, the Service Profile and the Operating
System. Before virtualization and UCS
(or HP Virtual Connect) this debate was a moot point because the three parts
were inseparable. Nowadays we may need
to reconsider how we use some of these terms.
The process of associating a Service Profile to a blade is a
two step process.
- Assign Service Profile to a slot.
- When blade is inserted, or if already present immediately
after step one, it is powered on and booted by a UCS internal PXE server to a
PnuOS. This utility OS provides UCS
access to the system for writing BIOS values (UUID, MAC, WWPN, etc.). The blade is then rebooted to the Service
Profile defined boot device.
When disassociating a Service Profile from a slot that has a
running blade in it, you are given an option to gracefully shutdown the
OS. This can be useful if you use the “Reassign
Service Profile” option to automate the shutdown>disassociate>associate
(to different slot)>power on process.
We got our first exposure to the KVM functionality
today. Overall it is similar to the
traditional (Java-based) Remote Console on HP’s iLO. You have the same cursor speed mismatch and a
lack of power options and remote media built into the KVM window. However, you do get a menu option to open the
remote media window in the KVM window. One
thing I noticed is that it will allow at least two connections to the same KVM,
which is very useful for collaborating.
Overall, the UCS KVM is a bit lacking compared to iLO’s new Integrated
Remote Console, but most of the shortcomings could be considered bells and
whistles.
Another quirk of the UCS GUI we noticed is that in the Equipment
tab of the Navigation pane, the icon of each blade does not change based on the
status of the hardware. A simple change
of color to indicate power state would save a ton of clicks. The number of clicks can quickly become a problem
given the huge amount of data provided by UCSM.
One side question that I received an answer to today was that
the UCS chassis has no cooling zones like the HP c-Class. Apparently Cisco felt that no zones is more efficient,
but is still studying the merits of both approaches to determine which is truly
more efficient.
When creating a Service Profile to enable stateless
computing you must specify MAC addresses and WWN in order to achieve the
aforementioned separation of hardware, physical identity and OS. When defining the MAC address, you can choose
a pool of MAC addresses or define a specific one. In either case the default Vendor ID is owned
by Cisco so it should only show up within UCS systems. Of course if you have multiple UCS domains,
you will have to manage the uniqueness between the multiple UCS Managers. When creating a pool of MACs or WWNs, there are
no pre-defined ranges like Virtual Connect provides. However it is very easy to define your own
pool. Simply enter a starting MAC,
define the number of address you want in the pool and it creates a pool of
sequential MACs.
There are actually two different types of pools that can be
created: Server pools, which contain blades, and identity pools, which are actually
several different pools for MAC, WWN, UUID, etc. In a stateless computing paradigm, the Service
Profile becomes the glue to hook all these different pools together. It is possible to attach more Service
Profiles to a server pool then there are physical blades in the pool. You’ll simply end up with Service Profiles
that are unassigned.
The server blade pool can be setup manually or in an
automated fashion by defining the characteristics (CPU type, # of CPU, amount
of RAM, slot #) of the blades that should belong to the pool. As blades are discovered by UCSM, they are
added to all automatic pools for which they meet the criteria. This means that a blade can be part of
multiple pools at once, but it still can only have one Service Profile
associated with it at a time.
This Server Farm approach will have a rather dramatic effect
on the approach to data center management.
In many organizations the hardware is owned by the business unit whose
budget was used to purchase the hardware.
This has led to an “I own that server, you can’t use it for anything
else” mentality to datacenter assets. Virtualization
has started to break down this approach due to the shared nature of the
resources. UCS will further erode this philosophy
due to the dynamic nature of the use-what-is-need-when-needed approach that a
Server Farm enables. We had a good
discussion around this topic and specifically what it will mean to our
customers and how they can best adjust to it (hint: VMware is already providing
some of the necessary tools).
Over lunch, Chris Haynes (Cisco) stopped in to help us
understand how Cisco architected the memory in the B250 to allow up to 384GB. There was a lot of information to absorb, so
I think I may leave this detail to a later post. Suffice it to say, I was very impressed and now
feel that Cisco can make it as a viable server company.
Another question that was clarified today was the effect of
UCSM and CMC failovers. Each UCSM (remember
one UCSM per Fabric Interconnect, configured in an Active/Passive cluster) has
a SAM controller. Each SAM controller
has a unique ID and communicates with it’s peer to determine who is the Active
node. The UCSM Active/Passive roles are
completely independent of the Active/Passive roles of the CMCs on the IOM. In other words, you can have the Active UCSM
on Fabric Interconnect A, but all the Active CMCs on the IOMs in Fabric B. The cross channel communication between the
Fabric Interconnects allows the communication to flow properly. I’m not sure what would happen should this
cross communication channel between Fabric Interconnects fail, but it’s worth
investigating.
The UCSM is an OEM version of BMC BladeLogic, but this
version of the BMC product is only available within UCS. James Hollinger, a BladeLogic for UCS
specialist at BMC, showed us some of the capabilities of a full implementation
of BladeLogic:
- Manager of mangers functionality across multiple UCS domains
- Create profile templates within BladeLogic in order to
create Service Profiles across multiple UCS domains
- Very granular Role Based Security (i.e. user has permissions
to stop one service, but no other permissions to the server itself)
- Additional workflow, including OS and application tasks
We finished the day performing the stateless computing lab
where we created Service Profiles with defined WWNs for connectivity to boot
volumes on the SAN. The lab didn’t
initially go smoothly since our boot from SAN Operating Systems consistently
crashed during boot up for all lab teams.
After pulling in additional Cisco resources, it was discovered that you
cannot migrate a Service Profile that boots from SAN and was built on a Menlo card
to a system with a Palo card (the same applies in reverse). This is due to incompatible drivers between
the two devices, so the OS starts to load, but cannot access it’s own boot disk
since it doesn’t have the proper drivers.